Hyrdoloop Solutions

Energy efficient semi plug-in refrigeration system powered by environment-friendly R290!

Learn more
Hydroloop systems

About the technology

Hydroloop refrigeration system is a cost-effective alternative to the remote refrigeration system. It connects multiple plug-in refrigerators and/or cold rooms to a glycol condensing system. The glycol system removes excess condensation heat through liquid pipes to the exterior of a building, or it can be used to heat the store and/or water. Hydroloop system ensures high energy efficiency and is also environmentally friendly, thanks to its ability to reuse the excess condensation heat formed during the refrigeration cycle.

Hydroloop systems | OMNI refrigeration

Hydroloop solutions

Explore the different types of Hydroloop Solutions

Hydroloop Glycol Systems

Glycol System

Hydroloop Glycol system connects plug-in refrigeration equipment fitted inside with compressors and all refrigeration cycle components to a glycol-cooled system with a plate condenser. The system efficiently removes excess condensation heat through liquid pipes to the exterior of a building or allows reusing it for heating the store or water. The pump station in the system eliminates the need for a machinery room and facilitates glycol circulation in a closed-cycle liquid system. An outdoor dry cooler is utilized in the system to enhance heat recovery.

Hydroloop systems | OMNI refrigeration

Glycol WPI System

Hydroloop Glycol WPI system connects plug-in refrigeration equipment, fitted inside with compressors and all refrigeration cycle components, to a glycol-cooled system with a plate condenser and a small-sized circulatory water pump. The integrated water pump facilitates glycol circulation in a closed-cycle liquid system and eliminates the need for the main pump station. The system efficiently removes excess condensation heat through liquid pipes to the exterior of a building or allows reusing it for heating the store or water. An outdoor dry cooler is used in the system to enhance heat recovery.

Hydroloop systems | OMNI refrigeration

Hydroloop condensing unit

Freors Hydroloop Condensing Unit allows coldrooms to connect to the Hydroloop system. The condensing units are intended to maintain the cold rooms’ temperatures. To achieve that, they are fitted with compressors and plate heat exchangers, which allow them to connect to the same Hydroloop line as other refrigerated display units. The system is easy to install and can be mounted on the top outside of the cold room with no additional space required or placed in the technical room. That makes it a compact refrigeration solution with maximised storage space.

Hydroloop systems | OMNI refrigeration

Hydroloop Hybrid Systems

Hybrid System

Hydroloop Hybrid system connects plug-in refrigeration equipment fitted inside with compressors and all refrigeration cycle components to a glycol-cooled system with air and plate condensers. The system allows combining two different condensation heat removal systems with the possibility of switching over. It can efficiently emit the heat directly into the shop via an air condenser mounted in the equipment or remove it through liquid pipes, where it can be reused to heat the water or removed outside the building. The pump station in the system eliminates the need for a machinery room and facilitates glycol circulation in a closed-cycle liquid system. An outdoor dry cooler is utilized in the system to enhance heat recovery.

Hydroloop systems | OMNI Refrigeration

Hybrid WPI system

Hydroloop Hybrid WPI system connects plug-in refrigeration equipment, fitted inside with compressors and all refrigeration cycle components, to a glycol-cooled system with a plate, air condensers, and a small circulatory water pump. The integrated water pump facilitates glycol circulation in a closed-cycle liquid system and eliminates the need for the main pump station. The system allows combining two different condensation heat removal systems with the possibility of switching over. It can efficiently emit the heat directly into the shop via an air condenser mounted in the equipment or remove it through liquid pipes, where it can be reused to heat the water or removed outside the building. An outdoor dry cooler is utilized in the system to enhance heat recovery.

Hydroloop systems | OMNI Refrigeration

Hydroloop System Comparisons

The comparison between all Hydroloop systems

Hydroloop systems | OMNI Refrigeration
Hydroloop systems | OMNI Refrigeration
Hydroloop systems | OMNI Refrigeration
Hydroloop systems | OMNI Refrigeration
Equipment
Semi plug-in, fitted with compressors and all refrigeration cycle components.
Through liquid pipes.
Plate condenser.
Pump station mounted anywhere in the store.
Pump station mounted anywhere in the store.
Small circulatory water pump integrated into equipment.
Small circulatory water pump integrated into equipment.
Can be connected to other systems (water or sales area heating) for heat reuse.
Outdoor dry cooler is used in the system for heat removal to the outside, when heat reusal is not needed.
Outdoor dry cooler is used in the system for heat removal to the outside, when heat reusal is not needed.
Outdoor dry cooler is used in the system for heat removal to the outside, when heat reusal is not needed.
Outdoor dry cooler is used in the system for heat removal to the outside, when heat reusal is not needed.
Can be connected to other systems (water or sales area heating) for heat reuse or can be reused for direct heat transfer into the shop area via air condenser mounted in the unit.
Can be connected to other systems (water or sales area heating) for heat reuse.
Can be connected to other systems (water or sales area heating) for heat reuse or can be reused for direct heat transfer into the shop area via air condenser mounted in the unit.
Plate condenser.
Plate and air condenser.
Plate and air condenser.
Directly or through liquid pipes.
Through liquid pipes.
Directly or through liquid pipes.
Fully /  semi plug-in, fitted with compressors and all refrigeration cycle components.
Semi plug-in, fitted with compressors and all refrigeration cycle components.
Fully / semi plug-in, fitted with compressors and all refrigeration cycle components.
Condensation heat removal
Condenser
Pump
Heat reusal  
Dry cooler

Reduce your store's operational costs!

Help the environment with our Hydroloop refrigeration solutions!

Choose this system

Get in touch with us us today.

Submit Enquiry
Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.

We use analytical cookies.

Ok, I understand
Manage preferences
Manage cookie preferences
Close
Your privacy choices
Strictly necessary
Performance and analytics
Targeting and advertising
Accept selection
Reject all